Saudi Arabia | Dubai | UAE | Abu Dhabi | Riyadh | Qatar | Dammam | Makkah | Bahrain | Sharjah | Jeddah | Oman
FPSC | PPSC | SPSC | KPPSC | AJKPSC | PPSC | Join Pak Navy | Join Pak Army | PAF | FIA | Police | Rangers
Medical | Bank | Teaching | Engineering | Data Entry | PHP | Latest Posts
Muhammad Nasrullah
Follow the permit to work System and safe operation policies and procedures Responsible for the Scheduled, breakdown, Corrective and preventive maintenance, Calibration, Troubleshooting, Repairing, Overhauling, Installation and Removal of all type’s instrumentationSuch as pressure, temperature, level, flow transmitters, Vortex Flowmeter, Electromagnetic flowmeter Radar based, Pressure switches, control valves, SOV, RTD, Thermocouples, PH Meter, Conductivity Meter, UV Detector, VFD, SDV, MOV, BDV, PSV,PRV, Booster relay, Quick Exhaust Relay, Electro pneumatic Positioner, I/P Convertor. Rosemount, E & H, Samson, Yokogawa, Siemens, ABB, Fisher, Floserve, Arca, Masoneilan, Murphy. F&G System of Net Safety, Honeywell like Gas detector, H2s detector, Fire Detector, Smoke Detector, Manual Call Point. Vibration probe, Vibration Transmitter, Vibration Switches and vibration Sensor. Analyzers Gas Chromatograph Daniel 500, 590 series, Moisture Ametek 3050, HCDPAmetek241, H2S, Ametek 933,H2S, Event Engineering 331 CO2, Ametek 5100, FloBOSS Emerson S600. Control System Siemens Simatic S7,200, 300, 400,Allen Bradley Logic 5555, 5000, Honey well S 900, Yokogawa CS3000, Supcon JX 300, ABB AC 800 M, Controller Yokogawa UT 350L,450,520,550. Perform root cause analysis of instrument failure. Ariel Reciprocating compressor for wellhead forward flow controlled by Allen Bradley PLC JMC Joint Metering Calibration with Customer SSGCL. Generators Caterpillar 3.1 MW, Waukesha Engines ESM, Instrumentation maintenance & troubleshooting. Participated in installation, Loop testing, pre-commissioning, commissioning, of Pakistan petroleum limited Gambat South gas processing facility GPF II, GPF IV, Gasco, Dolphin oil and gas field in UAE, Sitara Chemical Industries limited, and SML Disterly.G I S Gas insulated Sub-Station. Good working knowledge of P&ID. Maintain inventory Schedule to meet requirement of Spare parts and Material for Smooth plant Operation also quality inspection of newly procured instrumentation for stock. Preparation of daily/monthly/yearly job completion reports for keeping history and record. Preparation of Scope of work for annual and emergency turn around and safe execution of jobs. Ensure safe and efficient test equipment in the work shop. Ensure that all regulatory requirements are met. Ensure that all required records are maintained.


Contact Muhammad Nasrullah
(*) Verified recruiters can download candidate CV/ Resume. Login into your recruiter account for details.